Pro Plus_Máy đo nước đa chỉ tiêu cầm tay
Model: Pro Plus
Code: 6050000
Hãng sản xuất: YSI – Mỹ
Xuất xứ: Mỹ
1. Tính năng kỹ thuật:
- The Quatro cable attached to the Pro Plus allows you to utilize 4-ports to measure temperature/conductivity, DO, and any two ISEs among pH, ORP, ammonium, chloride, or nitrate creating an extremely powerful handheld multiparameter instrument.
- Interested in a Pro Series Product? Check out the trade in program currently going on (U.S. only).
Toughest:
- The Pro Plus instrument meets the demands of true field work. The instrument is rated to IP-67 standards even without the battery cover on. Other tough features include a 3-year warranty, Mil-spec connectors, rubber overmolded case, and a 2-year cable warranty. In-house testing procedures also include 1-meter drop tests from all angles to ensure expected field-durability.
- Easy-to-install cable weights; can be daisy-chained for additional weight*
- Rubber, over-molded IP-67 waterproof case (even without the battery cover)*
- 3-year instrument warranty
- 2-year cable warranty*
- Rugged cables, sensors, and military-spec connectors*
- Drop-tested 1 meter at all angles*
- Scratch-resistant lens; viewable with polarized glasses
Instrument floats:
- Weighted, user-replaceable multi-sensor design
Smartest:
- The instrument provides numerous benefits from the following features; 5,000 data-set memory, password protection, backlit display and keypad, graphic display with detailed Help functionality, re-cal prompts, user defined fields, detailed GLP, auto stable, Hold All Readings function, Data Manager software for the desktop, USB connection, auto-buffer recognition, and flexible folders and site lists for logging data.
- 5,000 data set memory
- Detailed on-screen Help function*
- Free, Data Manager desktop software and ProComm II saddle*
- Interval or single-event logging
- 100 folder & site list data structure*
- Password protection
- Detailed GLP data
- USB connection also powers the instrument
- 6-point cal with auto-buffer recognition*
- User-adjustable auto-stable with prompts*
- User-upgradeable software via waterproof USB port
- Recalibration prompts
- Search function filters user-defined data information*
- Backlit display AND keypad*
- Cable management kit included with all cables from 4- to 30-meters*
Most Versatile:
- Connect any Professional Series cable (excludes ODO cables) and probe option to the instrument and use the convenient cable management kit to keep everything simple and organized. Cable options range from 1-, 4-, 10-, 20-, and 30-meter choices (up to 100-meters on DO only cables). Use lab or field probes and switch between the two quickly. The Pro Plus makes an ideal lab BOD instrument with the proven self-stirring BOD probe. A convenient handstrap can be used on either side of the instrument. A complete family of accessories also increases the versatility of the Pro Plus. Choose among accessories including carrying cases, flow cells, cable weight, belt clip, tripod, and c-clamp.
- Adjustable right- or left-handed hand strap*
- Multiple user-replaceable sensor options and a choice of DO sensors*
- Multiple parameter options and cable lengths
- Lab-grade ISE sensors and BOD probe available to make a true lab/field instrument
- Languages - English, Spanish, German, French, Italian, Norwegian, Portuguese, Japanese, Chinese (Simplified and Traditional)
- Wide array of accessories are available from flow cells, to shoulder straps, to carrying cases
2. Thông số kỹ thuật:
Autostable
|
User-defined auto-stable function holds stable readings on display when criteria is met
|
Certifications
|
VCCI, FCC, C-Tick, 1-meter drop test, Assembled in USA, IP-67, WEEE, RoHS, CE
|
Connectivity / Communications
|
ProComm II communications saddle and USB cable included, user-upgradeable software via USB and website, USB 2.0
|
Connector
|
MS (military spec) waterproof with bayonet lock
|
Data Management
|
Data Manager desktop software included; 100 user-defined folders and site namesMinimum PC requirements;•Windows 2000 with SP4 (minimum) or XP with SP2 (minimum)•300 MHz or higher Pentium-compatible CPU•128 MB of RAM or higher•80 MB or more of free hard-disk space•USB 2.0•Microsoft.NET (installed with Data Manager)
|
Desktop Software Compatible
|
100 user-defined folders and site names Minimum PC requirements, •Windows 2000 with SP4 (minimum) or XP with SP2 (minimum) •300 MHz or higher Pentium-compatible CPU •128 MB of RAM or higher •80 MB or more of free h, Data Manager desktop software included
|
Digital / Digital Sensors
|
Analog
|
GLP Compliance
|
detailed GLP information is stored and is available to view, download or print, Yes
|
Graphic Display
|
backlit display AND keypad, Graphic display with detailed Help
|
Languages
|
English, Portuguese, Italian, German, Chinese (Simplified and Traditional), French, Japanese, Spanish, Norwegian
|
Logging Capabilities
|
Single or Continuous
|
Measurement Range
|
Dissolved Oxygen % air saturation-0 to 500% Temperature--5 to 70°C Conductivity-0 to 200 mS/cm Salinity-0 to 70 ppt pH-0 to 14 units ORP-1999 to +1999 mV Ammonium-0 to 200 mg/L-N Nitrate-0 to 200 mg/L-N Chloride-0 to 1000 mg/L Total Dissolved Solids(TDS)-0 to 100 g/L Barometer-375 to 825 mmHg
|
Memory
|
100 GLP files, 5,000 data sets (data, date, time, user-defined info)
|
Multiparameter
|
Yes
|
Operating pH Range
|
0 to 14 units
|
Operating Temperature
|
-10 to 60°C
|
Parameters Measured
|
Temperature, Dissolved Oxygen, pH, ORP/Redox, Conductivity, TDS, Ammonia, Ammonium, Nitrate, Chloride,Built-in barometer
|
Power
|
2 alkaline C-cells provide 80 continuous hours at ambient temperature without backlight, ProComm II saddle provides USB power or optional wall power, cigarette lighter, and universal cell phone charger options
|
Sampling
|
Yes
|
Storage Temperature
|
-20 to 70°C
|
Unit of Measure
|
°F, Temperature- °C, Barameter-mmHg, Nitrate-mg/L-N, Dissolved Oxygen-%, Chloride-mg/L, air saturation, ORP-mV, Total Dissolved Solids(TDS)-g/L, Ammonium-mg/L-N, Salinity-ppt, mg/L, pH-units, Conductivity-mS/cm
|
User Calibratable
|
Yes
|
User Replaceable
|
Yes
|
Warranty
|
3-year instrument; 2-year field cables
|
Waterproof
|
IP-67 (even with the battery cover off), floats
|
Specification
| |
Barometer
|
Built-in barometer
|
Buffer Recognition
|
Auto buffer recognition for US and NIST buffers
|
Cables: Field
|
Standard lengths of 1, 4, 10, 20, or 30 meters - up to 100 meters on DO only cables; 4- through 30-meter cables include a cable management kit
|
Cables: Lab
|
BOD sensor includes 2-meter cable; 1 or 4 meters on lab pH, ORP and pH/ORP cables
|
Certifications
|
RoHS, CE, WEEE, C-Tick, VCCI, FCC, IP-67, 1-meter drop test, Assembled in USA
|
Connectivity
|
USB 2.0; ProComm II communications saddle and USB cable included; user-upgradeable software via USB and website
|
Connector
|
MS (military spec) waterproof with bayonet lock
|
Data Management
|
Data Manager desktop software included; 100 user-defined folders and site names. Minimum PC requirements:
· Windows 2000 with SP4 (minimum) or XP with SP2 (minimum)
· 300 MHz or higher Pentium-compatible CPU
· 128 MB of RAM or higher
· 80 MB or more of free hard-disk space
· USB 2.0
· Microsoft.NET (installed with Data Manager)
|
Data Memory
|
5,000 data sets (data, date, time, user-defined info); 100 GLP files
|
Dimensions
|
8.3 cm width x 21.6 cm length x 5.6 cm depth (3.25 in x 8.5 in x 2.21 in)
|
Display
|
Graphic display with detailed Help; backlit display AND keypad
|
DO Membrane Response Times(T95; 100%-0) and Flow Dependence
|
1.25 mil PE = 8 seconds and 6 in/sec flow
2.0 mil PE = 17 seconds and 3 in/sec flow 1 mil Teflon® = 18 seconds and 12 in/sec flow |
DO Sensors
|
Polarographic or galvanic field sensors; self-stirring polarographic BOD sensor for the lab
|
Flow Cell
|
Single, dual and multiparameter Quatro cable all flow cell compatible
|
GLP Compliance
|
Yes; detailed GLP information is stored and is available to view, download or print
|
Languages
|
English, Spanish, German, French, Italian, Norwegian, Portuguese, Japanese, Chinese (Simplified & Traditional)
|
Logging Modes
|
Single point or Continuous
|
Power
|
2 alkaline C-cells provide 80 continuous hours at ambient temperature without backlight; ProComm II saddle provides USB power or optional wall power, cigarette lighter, and universal cell phone charger options
|
Temperature: Operating
|
-10 to 60°C (14 to 140°F)
|
Temperature: Storage
|
-20 to 70°C (-4 to 158°F)
|
User ID
|
Optional user ID for data security
|
Warranty
|
3-year instrument; 2-year field cables
|
Waterproof
|
IP-67 (even with the battery cover off); floats
|
Weight
|
475 grams (1.05 lbs)
|
3. Thông tin đặt hàng:
· Step 1: Order Instrument
SKU
|
Description
|
6050000
|
Instrument, includes Data Manager software, the ProComm II communications saddle, and USB cable
|
· Step 2: Order Cable(s)
SKU
|
Description
|
60510
|
1, 4, 10, 20 or 30 meter: ISE*/temp
|
60520
|
1, 4, 10, 20, 30 or up to100 meters**: DO/temp
|
60530
|
1, 4, 10, 20 or 30 meter: conductivity/temp
|
6051010
|
1, 4, 10, 20 or 30 meter: ISE/ISE/temp
|
6051020
|
1, 4, 10, 20 or 30 meter: ISE/DO/temp
|
6051030
|
1, 4, 10, 20 or 30 meter: ISE/conductivity/temp
|
6052030
|
1, 4, 10, 20 or 30 meter: DO/conductivity/temp
|
605790
|
1, 4, 10, 20 or 30 meter: ISE/ISE/DO/conductivity/temp
|
605107
|
1–meter single junction pH sensor & cable
|
605177
|
4–meter single junction pH sensor & cable
|
605108
|
1–meter single junction ORP sensor & cable
|
605178
|
4–meter single junction ORP sensor & cable
|
605109
|
1–meter single junction pH/ORP sensor & cable
|
605179
|
4–meter single junction pH/ORP sensor & cable
|
· Step 3: Order Sensor(s)
SKU
|
Description
|
605202
|
Galvanic DO
|
605203
|
Polarographic DO
|
605780
|
Self-stirring BOD (2-meter cable included)
|
605101
|
pH (ISE)
|
605102
|
ORP (ISE)
|
605103
|
pH/ORP combination (ISE)***
|
605104
|
Ammonium (ISE)
|
605105
|
Chloride (ISE)
|
605106
|
Nitrate (ISE)
|
** Special order cables in 10-meter increments up to 100 meter available
*** Not recommended on 6051010 or 605790 cables. Only pH would appear