Thứ Năm, 1 tháng 6, 2017

Multi-parameter analysers Model: C6010 •C6030 Manufacture: CONSORT – Belgium Origin: Belgium

Multi-parameter analysers
Model: C6010 •C6030
Manufacture: CONSORT – Belgium
Origin: Belgium
Reference at: http://www.consort.be/

1.      Over View:
pH:
-          Multi-point (1...5) calibration for more linearity.
-          Selectable resolution from 0.001 pH to 0.1 pH.
-          Automatic calibration with any of eleven pre-programmed and five user specified pH buffers
-          Accepts pH electrodes with any zero point (Eo) between ±999 mV.
mV:
-          Features mV calibration for accurate ORP measurements.
-          Selectable resolution from 0.1 mV to 1 mV.
Ion: (C6030 only)
-          Direct concentration measurement.
-          Multi-point (2...5) calibration and an additional blank correction for measuring low concentrations.
-          Stores calibration curves for up to 9 different electrodes.
Conductivity:
-          Multi-point (1...3) calibration for more linearity.
-          An electrode with a typical cell constant of 1
cm-1 permits to meas-ure from 0.01 µS/cm to 200 mS/cm in five ranges.
-          An electrode with a typical cell constant of 0.1 cm-1 permits to measure from 0.001 µS/cm to 20 mS/cm in five ranges.
-          An electrode with a typical cell constant of 10 cm-1 permits to measure from 0.1 µS/cm to 2000 mS/cm in five ranges.
-          Automatically selects correct range and frequency.
-          Selectable reference temperature: 20° or 25°C.
-          Automatic calibration with any of three preprogrammed and three user specified standard solutions.
-          Allows to lock the initial conductivity range to avoid non-linear titration curves.
-          Accurate low conductivity measurements by eliminating the capaci-tive component of the electrode and its cable (avoid the use of long
cables!)
Dissolved oxygen:
-          Operates with a galvanic dissolved oxygen electrode requiring no polarisation time and no zero calibration.
-          Selectable resolution from 0.01 mg/l (0.1%) to 0.1 mg/l (1%).
-          Manual salinity compensation 0-40.
-          Automatic air pressure compensation 600-1300 hPa.
Temperature:
-          Reads temperatures with 0.1°C resolution.
-          Manual or automatic temperature compensation.
-          Calibrates temperature probe for quality measurements.
Inputs:
-          One common input for all ranges + corresponding reference input.
-          One input for a Pt1000 automatic temperature probe.
Outputs:
-          Galvanically isolated USB communication port for connection to a computer.
Display:
-          Large bright LCD screenfor better readability.
-          A white backlight automatically illuminates when operated on the mains.
-          Stability indicator prompts the user when readings should be taken.
-          Hold function allows to freeze the display for convenient reading or recording.
-          The interactive LCD screen provides step by step instructions in the language of your choice (English, Dutch, French, German).
-          Real-time clock displays time and date.
-          Shows a GLP report on the LCD screen.
Data-logging:
-          Up to 12000 data sets can be stored manually or at a programmable interval.
-          Allows to mix data from all ranges in the same table.
Cabinet:
-          Robust dust and splash-proof cabinet.
Special features:
-          Three year warranty.
-          Calibration reminder: 0...999 h.
-          Programmable recorder output.
-          Programmable identification number for use with a printer or computer.
-          Password protection prevents any unauthorised modification of the instrument's settings.
-          Two way communication with a printer or computer using USB.
-          Mains and rechargeable battery operation with programmable automatic switch off.
-          Shows percentage of remaining battery capacity.
-          Optional 12 V car adaptor.
GLP:
-          All procedures for a "Good Laboratory Practice" are on board.
Pre-programmed standards:
-          pH buffers: 1.68, 2.00, 4.00, 4.01, 6.87, 7.00, 9.18, 9.21, 10.01, 12.00, 12.45 (at 25°C).
-          Conductivity: 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm (at 25°C).

2.      Technical Data:
pH:
-          Range: -2...+16 pH
-          Resolution: 0.001 pH
-          Accuracy: 0.1% ± 1 digit
-          Calibration: 1...5 points
-          Buffers:11 pre-programmed; 5 user specified
-          Temperature compensation: -5...+105°C
-          ISO-pH: 6...8 pH
-          Slope: 80...120%
-          Zero point (Eo): ±999 mV
mV:
-           Range: ±2000 mV
-          Resolution: 0.1 mV
-          Accuracy: 0.1% ± 1 digit
-          Calibration: 1 point
ION: (C6030 only)
-           Range: 0.01 ng/l...100 g/l
-          Resolution: 3 digits
-          Accuracy: 0.5% ± 1 digit
-          Calibration: 2...5 points + blank 9 individual curves
CONDUCTIVITY:
-           Range (cc dependent): 0...2000 mS/cm
-          Resolution (cc dependent): 0.001 µS/cm
-          Accuracy: 0.5% f.s. of range
-          Calibration: 1...3 points
-          Standards: 3 pre-programmed; 3 user specified
-          Cell constant (cc): 0.07...13 cm-1
-          Temperature compensation: -5...+105°C
-          Reference temperature: 20° or 25°C
-          Temperature coefficient: natural waters (EN27888)
-          Range lock
-          Capacitive compensation
RESISTIVITY:
-           Range: 0...200 MΩ.cm
-          Resolution: 1 Ω.cm
SALINITY:
-          Range: 0.0...70.0
-          Reference temperature: 15°C
TDS:
-           Range: 0...100 g/l
-          Resolution: 0.01 mg/l
DISSOLVED OXYGEN:
-           Range: 0...60 mg/l (0...600%)
-          Resolution: 0.01 mg/l (0.1%)
-          Accuracy: 1% ± 1 digit
-          Calibration: 1 point
-          Temperature compensation: 0...50°C
-          Salinity compensation: 0...40
-          Air pressure compensation: 600...1300 hPa
TEMPERATURE:
-           Range: -5...+105°C
-          Resolution: 0.1°C
-          Accuracy: 0.1°C
-          Calibration: 1 point
AIR PRESSURE:
-           Range: 600...1300 hPa
-          Calibration: 1 point
INPUTS:
-           Measurement: BNC, 1012
-          Temperature: 2 banana, for Pt1000
CALIBRATION:
-           Reminder: 0...999 h
-          GLP
DISPLAY:
-           LCD: 128x64 pixels
-          White backlight
-          Hold function
-          Selectable resolution
-          Real time clock
COMMUNICATION:
-           Interface with computer USB, insulated
DATA-LOGGING:
-      Data sets: 12000 + °C/date/time
-          Modes all (9)
-          Manual or timed
-          Interval: 1...9999 s
SECURITY:
-           Identification number
-          Password protection
AMBIENT CONDITIONS:
-           Temperature: 0...40°C
-          Humidity: 0...95%, non condensing
POWER SUPPLY:
-           Mains: 100...240 VAC, 50/60 Hz
-          Low voltage: 9...15 VDC
-          Batteries: 4x1.2 V, AA, NiMH
DIMENSIONS (WxDxH): 12x25x5 cm
WEIGHT: Meter 600 g

3.      Order Info:

Item
Code
Description
01
C6010
pH/conductivity/DO meter + USB cable
02
C6030
pH/Ion/conductivity/DO meter + USB cable
03
C60x0P
Meter kit for pH: meter + pH/ATC electrode SP10T + 2x50 ml buffers (pH 4 and 7) + 50 ml electrolyte (3M KCl) + carrying case
04
C60x0K
Meter kit for conductivity: meter + conductivity/ATC electrode SK10T + 50 ml conductivity standard (0.01 M KCl) + carrying case
05
C60x0Z
Meter kit for oxygen: meter + dissolved oxygen electrode SZ10T + carrying case
06
C60x0T
Meter kit complete: meter + pH/ATC electrode SP10T + conductivity/ATC electrode SK10T + dissolved oxygen electrode SZ10T + 2x50 ml buffers (pH 4 and 7) + 50 ml electrolyte (3M KCl) + 50 ml conductivity standard (0.01 M KCl) + carrying case
07
C60x0X
Meter kit without electrodes: meter + 2x50 ml buffers (pH 4 and 7) + 50 ml electrolyte (3M KCl) + 50 ml conductivity standard (0.01 M KCl) + carrying case
08
SH300
Flexible electrode holder (optional)
09
A4049
Car adaptor, 12 V (optional)