Multi-parameter analysers
Model: C3410 •C3420 •C3430
Manufacture: CONSORT – Belgium
Origin: Belgium
Reference at: http://www.consort.be/
1. Overview:
pH:
- Multi-point (1...5) calibration for more linearity.
- Selectable resolution from 0.001 pH to 0.1 pH.
- Automatic calibration with any of eleven pre-programmed and five user specified pH buffers.
- Accepts pH electrodes with any zero point (Eo) between ±999 mV.
mV:
- Features mV calibration for accurate ORP measurements.
- Selectable resolution from 0.1 mV to 1 mV.
Ion (C3430, C3431 only):
- Direct concentration measurement.
- Multi-point (2...5) calibration and an additional blank correction for measuring low concentrations.
Conductivity:
- Multi-point (1...3) calibration for more linearity.
- The 4-pole design reduces considerably the problems of polarisation and fouling. A 4-pole electrode permits to measure with the highest degree of accuracy and linearity.
- An electrode with a typical cell constant of 1
cm-1 permits to measure from 0.01 µS/cm to 200 mS/cm in five ranges.
- An electrode with a typical cell constant of 0.1
- cm-1permits to measure from 0.001 µS/cm to 20 mS/cm in five ranges.
- An electrode with a typical cell constant of 10 cm-1permits to measure from 0.1 µS/cm to 2000 mS/cm in five ranges.
- Automatically selects correct range and frequency.
- Selectable reference temperature: 20° or 25°C.
- Automatic calibration with any of three preprogrammed and three user specified standard solutions.Create your own standard/temp. tables!
- Allows to lock the initial conductivity range to avoid non-linear titration curves.
- Accurate low conductivity measurements by eliminating the capacitive component of the electrode and its cable (avoid the use of long cables!).
Dissolved oxygen: (C3420, C3421, C3430, C3431 only)
- Operates with a galvanic dissolved oxygen electrode requiring no polarisation time and no zero calibration.
- Selectable resolution from 0.01 mg/l (0.1%) to 0.1 mg/l (1%).
- Automatic air pressure compensation 600-1300 hPa.
Temperature:
- Reads temperatures with 0.1°C resolution.
- Manual or automatic temperature compensation (O2: 0...50°C).
- Calibrates temperature probe for quality measurements.
Inputs:
- Two inputs for pH, mV, Ion, dissolved oxygen or conductivity + cor-responding temperature and reference inputs.
- Two extra DIN-8 connectors for 4-pole conductivity electrodes with built-in Pt1000.
Outputs: Two versions available:
- C3410, C3420, C3430: with USB communication port (galvanically isolated) and RS232 interface.
- C3411, C3421, C3431: with Ethernet communication port and RS232 interface.
Display:
- A large bright LCD screen with white backlight enables to view all channels individually or simultaneously.
- Stability indicator prompts the user when readings should be taken.
- Hold function allows to freeze the display for convenient reading or recording.
- The interactive LCD screen provides step by step instructions in the language of your choice (English, Dutch, French, German).
- Real-time clock displays time and date.
- Shows a GLP report on the LCD screen.
Data-logging:
- Up to 12000 data sets can be stored manually or at a programmable interval.
- Allows to mix data from all ranges in the same table.
Cabinet:
- Robust dust and splash-proof cabinet.
- An optional wall mounting kit allows to fix the meter to any wall making more space available on the desk.
Special features:
- Two-way communication with a computer using USB, Ethernet or RS232.
- Can be programmed to continue automatically with the measure-ments or data-logging after a power failure.
- Password protection prevents any unauthorised modification of the instrument's settings.
- No electrical interference between pH/ORP/Ion and conductivity electrodes in the same solution.
- Optional 12 V car adaptor.
- Three year warranty.
GLP:
- All procedures for a "Good Laboratory Practice" are on board.
Pre-programmed standards:
- pH buffers: 1.68, 2.00, 4.00, 4.01, 6.87, 7.00, 9.18, 9.21, 10.01, 12.00, 12.45 (at 25°C).
- Conductivity: 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm (at 25°C).
2. Technical Data:
pH:
- Range: -2...+16 pH
- Resolution: 0.001 pH
- Accuracy: 0.1% ± 1 digit
- Calibration: 1...5 points
- Buffers: 11 pre-programmed,5 user specified
- Temperature compensation: -5...+105°C
- ISO-pH: 6...8 pH
- Slope 80...120%
- Zero point (Eo) ±999 mV
mV:
- Range: ±2000 mV
- Resolution: 0.1 mV
- Accuracy: 0.1% ± 1 digit
- Calibration: 1 point
ION: (C343x only)
- Range: 0.01 ng/l...100 g/l
- Resolution: 3 digits
- Accuracy: 0.5% ± 1 digit
- Calibration: 2...5 points + blank
CONDUCTIVITY:
- Range (cc dependent): 0...2000 mS/cm
- Resolution (cc dependent): 0.001 µS/cm
- Accuracy: 0.5% f.s. of range
- Calibration: 1...3 points
- Standards: 3 pre-programmed, 3 user specified
- Cell constant (cc): 0.07...13 cm-1
- Temperature compensation: -5...+105°C
- Reference temperature: 20° or 25°C
- Temperature coefficient: natural waters (EN27888)
- Range lock
- Capacitive compensation
RESISTIVITY:
- Range: 0...200 MΩ.cm
- Resolution: 1 Ω.cm
SALINITY:
- Range: 0.0...70.0
- Reference temperature: 15°C
TDS:
- Range: 0...100 g/l
- Resolution: 0.01 mg/l
DISSOLVED OXYGEN: (C342x, C343x only)
- Range: 0...60 mg/l (0...600%)
- Resolution: 0.01 mg/l (0.1%)
- Accuracy: 1% ± 1 digit
- Calibration: 1 point
- Temperature compensation: 0...50°C
- Salinity compensation: 0...40
- Air pressure compensation: 600...1300 hPa
TEMPERATURE:
- Range: -5...+105°C
- Resolution: 0.1°C
- Accuracy: 0.1°C
- Calibration: 1 point
AIR PRESSURE: (C342x, C343x only)
- Range: 600...1300 hPa
- Calibration: 1 point
CHANNELS:
- Measurement: 2
- Temperature: 2
INPUTS:
- Measurement: 2 BNC, 1012Ω
- Temperature: 2x2 banana, for Pt1000
- Four-pole conductivity cell: 2 DIN-8
CALIBRATION:
- Reminder: 0...999 h
- GLP
DISPLAY:
- LCD: 240x64 pixels
- White backlight
- Hold function
- Selectable resolution
- Real time clock
COMMUNICATION:
- Interface with computer: USB or Ethernet
- RS232, baud rate: 1200...115200 b/s
- Printer
DATA-LOGGING:
- Data sets: 12000 + °C/date/time
- Modes all
- Manual or timed
- Interval: 1...9999 s
SECURITY:
- Identification number
- Password protection
AMBIENT CONDITIONS:
- Temperature: 0...40°C
- Humidity: 0...95%, non condensing
POWER SUPPLY:
- Mains 100...240 VAC, 50/60 Hz
- Low voltage 9...15 VDC
DIMENSIONS (WxDxH): 26x18x9 cm
WEIGHT: Meter 1 kg
3. Order Info:
Item
|
Code
|
Description
|
01
|
C3410
|
pH/conductivity meter (USB version) + USB cable
|
02
|
C3411
|
pH/conductivity meter (Ethernet version) + UTP cable
|
03
|
C3420
|
pH/conductivity/DO meter (USB version) + USB cable
|
04
|
C3421
|
pH/conductivity/DO meter (Ethernet version) + UTP cable
|
05
|
C3430
|
pH/Ion/conductivity/DO meter (USB version) + USB cable
|
06
|
C3431
|
pH/Ion/conductivity/DO meter (Ethernet version) + UTP cable
|
07
|
C34xxX
|
Meter kit without electrodes: meter + 2x50 ml buffers (pH 4 and 7) + 50 ml electrolyte (3M KCl) + 50 ml conductivity standards (0.01 M KCl) + UTP cable
|
08
|
SH300
|
Flexible electrode holder (optional)
|
09
|
A4800
|
Wall mounting kit (optional)
|
10
|
A4049
|
Car adaptor, 12 V (optional)
|
Không có nhận xét nào: